{"created":"2023-05-15T12:05:25.018727+00:00","id":10084,"links":{},"metadata":{"_buckets":{"deposit":"e132106f-cf71-49c9-8408-61883ffadb71"},"_deposit":{"created_by":3,"id":"10084","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"10084"},"status":"published"},"_oai":{"id":"oai:iwate-u.repo.nii.ac.jp:00010084","sets":["1515:1519"]},"author_link":["62560","62559","62558","62561"],"item_16_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2008-10-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"73","bibliographicPageStart":"67","bibliographicVolumeNumber":"16","bibliographic_titles":[{"bibliographic_title":"ECS Transactions"}]}]},"item_16_date_6":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-09-22"}]},"item_16_description_12":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"The objective is to develop a methodology to analyze cathepsin L (Cat L) activity derived from the stratum corneum as an index of skin conditions. In this paper, a disposable type immuno-chromatographic test-strip (test-strip) is proposed for Cat L analysis. A fabricated test-strip for Cat L analysis consists of a sample pad, a conjugate pad, a nitrocellulose membrane and absorption pad. After dropping a sample, it was needed 90 s to reach the solution at the test-line on the test-strip. Three min after dropping, a reddish purple colored band was appeared as the test-line. The band visually observed clearly when the concentration of Cat L of the standard solution over 0.01 U/l. It was indicated a possibility of the disposable type immuno-chromatographic test-strip for the analysis of Cat L of skin.","subitem_description_type":"Other"}]},"item_16_publisher_14":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"The Electrochemical Society"}]},"item_16_relation_26":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1149/1.2981106","subitem_relation_type_select":"DOI"}}]},"item_16_rights_18":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© The Electrochemical Society, Inc. 2008. All rights reserved. Except as provided under U.S. copyright law, this work may not be reproduced, resold, distributed, or modified without the express permission of The Electrochemical Society (ECS). The archival version of this work was published in ECS Transactions, 16(11), pp.67-73, (2008)"}]},"item_16_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1938-5862","subitem_source_identifier_type":"ISSN"}]},"item_16_text_4":{"attribute_name":"著者(機関)","attribute_value_mlt":[{"subitem_text_value":"Graduate School of Engineering, Iwate University"},{"subitem_text_value":"Graduate School of Engineering, Iwate University"},{"subitem_text_value":"Graduate School of Engineering, Iwate University"},{"subitem_text_value":"Procter & Gamble Japan K.K."}]},"item_16_version_type_27":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Yamaguchi, Masaki"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Kosada, Shoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Tahara, Yusuke"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"Date, Akira"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-14"}],"displaytype":"detail","filename":"ecst-v16i11p67-73.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"ecst-v16i11p67-73.pdf","url":"https://iwate-u.repo.nii.ac.jp/record/10084/files/ecst-v16i11p67-73.pdf"},"version_id":"7c3e5b07-0d56-4776-9d28-5c4feeba45df"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Immuno-chromatographic Test-strip for Skin Cathepsin L Analysis","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Immuno-chromatographic Test-strip for Skin Cathepsin L Analysis"}]},"item_type_id":"16","owner":"3","path":["1519"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-09-22"},"publish_date":"2011-09-22","publish_status":"0","recid":"10084","relation_version_is_last":true,"title":["Immuno-chromatographic Test-strip for Skin Cathepsin L Analysis"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-16T11:47:09.018784+00:00"}