Item type |
学術雑誌論文 / Journal Article(1) |
公開日 |
2021-10-04 |
タイトル |
|
|
タイトル |
Magnetocardiography Current Source Estimation using Multiple Spatial Filters |
言語 |
|
|
言語 |
eng |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
magnetocardiography |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
current source estimation |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
spatial filter |
キーワード |
|
|
主題Scheme |
Other |
|
主題 |
eLORETA |
資源タイプ |
|
|
資源タイプ識別子 |
http://purl.org/coar/resource_type/c_6501 |
|
資源タイプ |
journal article |
アクセス権 |
|
|
アクセス権 |
metadata only access |
|
アクセス権URI |
http://purl.org/coar/access_right/c_14cb |
著者 |
KOBAYASHI, K.
IWAI, M.
ONO, Y.
SUN, W.
SUGIMACHI, M.
KUSANO, K.
SHISHIDO, T.
|
著者(機関) |
|
|
値 |
Faculty of Science and Engineering, Iwate Univ. |
著者(機関) |
|
|
値 |
Faculty of Science and Engineering, Iwate Univ. |
著者(機関) |
|
|
値 |
Faculty of Science and Engineering, Iwate Univ. |
著者(機関) |
|
|
値 |
Faculty of Engineering, Kindai Univ. |
著者(機関) |
|
|
値 |
National Cerebral and Cardiovascular Center Research Institute |
著者(機関) |
|
|
値 |
National Cerebral and Cardiovascular Center Research Institute |
著者(機関) |
|
|
値 |
National Cerebral and Cardiovascular Center Research Institute |
登録日 |
|
|
日付 |
2021-10-04 |
書誌情報 |
Journal of the Magnetics Society of Japan
巻 45,
号 5,
p. 131-135,
発行日 2021-09-01
|
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
18822932 |
ISSN |
|
|
収録物識別子タイプ |
ISSN |
|
収録物識別子 |
18822924 |
抄録 |
|
|
内容記述タイプ |
Abstract |
|
内容記述 |
In this study, cardiac current source localization was simulated using the spatial filter method. We estimated current sources using data from two measurement surfaces, i.e., the front and back of the subject, to reduce the large spatial extension in the depth direction. Three methods for creating spatial filters were developed using the exact low-resolution brain electromagnetic tomography method based on different creation procedures. The first method is a general method that has been conventionally used to create a spatial filter (64ch spatial filter) using a 64ch sensor on the front side. The second method is to create a spatial filter (128ch spatial filter) using two 64ch sensors on the front and back sides as a 128ch sensor. The third method is to create two spatial filters separately and use them as one spatial filter (2 × 64ch spatial filter). In this case, different Tikhonov regularization parameters can be determined on the front and back sides, and optimum noise immunity can be given to each. The accuracy of the estimated current sources using the three types of spatial filters was examined using simulation and MCG data. The results show that the 2 × 64 spatial filter has the highest estimation accuracy and suppresses the large spatial extension of the estimated current sources. |
出版者 |
|
|
出版者 |
日本磁気学会 |
関係URI |
|
|
|
識別子タイプ |
URI |
|
|
関連識別子 |
https://www.jstage.jst.go.jp/article/msjmag/45/5/45_2109R003/_article/-char/ja |
|
|
関連名称 |
Magnetocardiography Current Source Estimation using Multiple Spatial Filters |
権利 |
|
|
権利情報 |
© 2021 日本磁気学会 |
NCID |
|
|
収録物識別子タイプ |
NCID |
|
収録物識別子 |
AA12297999 |
DOI |
|
|
|
識別子タイプ |
DOI |
|
|
関連識別子 |
info:doi/10.3379/msjmag.2109R003 |