{"created":"2023-05-15T12:10:14.854512+00:00","id":15905,"links":{},"metadata":{"_buckets":{"deposit":"4a9ff687-5904-4041-9f87-48f18290ba0f"},"_deposit":{"created_by":19,"id":"15905","owners":[19],"pid":{"revision_id":0,"type":"depid","value":"15905"},"status":"published"},"_oai":{"id":"oai:iwate-u.repo.nii.ac.jp:00015905","sets":["1515:1519"]},"author_link":["95972","95974","95973","95971","95735","95732","95734","95733","95975","95736"],"item_16_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"Abstract","bibliographicPageStart":"400","bibliographicVolumeNumber":"Annual59","bibliographic_titles":[{"bibliographic_title":"生体医工学"},{"bibliographic_title":"Transactions of Japanese Society for Medical and Biological Engineerin","bibliographic_titleLang":"en"}]}]},"item_16_date_6":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2023-01-30"}]},"item_16_description_11":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"昨今,新型コロナウイルス感染症の感染拡大が世界的問題となっており,重症化する感染者数も増加傾向にある.そのため,「症状の急性増悪」を評価する一つの指標である「酸素飽和度の低下」を計測することが可能な酸素飽和度計の需要が高まっている.一般的に酸素飽和度を計測する方法として,血液に光を照射した際の吸光量は光の波長と酸素飽和度に依存することを利用した方法が採用されている.現在普及している医療機器のほとんどは,赤外光と赤色光のヘモグロビン吸光特性の違いを利用して酸素飽和度を計測する計測方法を採用しており,自然光などの外乱光を防ぐために接触式のプローブを装着して計測を行う.そこで本研究では赤外光と赤色光と同様に赤色,緑色,青色にも同様にヘモグロビンの吸光特性に違いがあることに着目し,一般的にスマートホンなどにも搭載されているRGBカメラを用いて酸素飽和度を推定する手法を提案・検討を行った.本手法は,RGBカメラを利用することによりより簡便に計測できる上,非接触で計測できるようになるため現在のニーズに合った計測方法といえる.販売されている医療機器の酸素飽和度計と同時計測を行い提案手法の計測精度を確認した.その結果,非接触でのRGBカメラを用いた酸素飽和度推定が可能であることが示唆されたため報告する.","subitem_description_type":"Abstract"}]},"item_16_description_12":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"Recently, COVID-19 infection has become a global problem, and the number of people infected with the disease is increasing. As a result, there is increasing demand for an oxygen saturation meter that can measure a decrease in oxygen saturation, which is one index for evaluating the acute exacerbation of symptoms. Generally, the method adopted for measuring oxygen saturation relies on a relation between the amount of light absorption by blood at particular wavelengths, and the blood's oxygen saturation. Therefore, in this research, we focused on the difference in the absorption characteristics of hemoglobin for red, green, and blue light, and we proposed and evaluated a method for estimating oxygen saturation using visible light. As a result, we suggest that oxygen saturation can be estimated using a non-contact RGB camera.","subitem_description_type":"Other"}]},"item_16_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"95971","nameIdentifierScheme":"WEKO"}],"names":[{"name":"IWAI, Morio"}]},{"nameIdentifiers":[{"nameIdentifier":"95972","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KOBAYASHI, Koichiro"}]},{"nameIdentifiers":[{"nameIdentifier":"95973","nameIdentifierScheme":"WEKO"}],"names":[{"name":"HONMA, Naoki"}]},{"nameIdentifiers":[{"nameIdentifier":"95974","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SATO, Atushi"}]},{"nameIdentifiers":[{"nameIdentifier":"95975","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ジョーンズ, マイケル"}]}]},"item_16_link_13":{"attribute_name":"抄録(URL)","attribute_value_mlt":[{"subitem_link_text":"RGBカメラを用いた非接触酸素濃度推定技術に関する研究","subitem_link_url":"https://www.jstage.jst.go.jp/article/jsmbe/Annual59/Abstract/Annual59_400/_article/-char/ja/"}]},"item_16_publisher_14":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本生体医工学会"}]},"item_16_relation_26":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"info:doi/10.11239/jsmbe.Annual59.400","subitem_relation_type_select":"DOI"}}]},"item_16_rights_18":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"© 2021 日本生体医工学会"}]},"item_16_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"18814379","subitem_source_identifier_type":"ISSN"},{"subitem_source_identifier":"1347443X","subitem_source_identifier_type":"ISSN"}]},"item_16_text_4":{"attribute_name":"著者(機関)","attribute_value_mlt":[{"subitem_text_value":"岩手大学理工学部"},{"subitem_text_value":"岩手大学理工学部"},{"subitem_text_value":"岩手大学理工学部"},{"subitem_text_value":"株式会社エクォス・リサーチ"},{"subitem_text_value":"株式会社エクォス・リサーチ"}]},"item_16_version_type_27":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岩井, 守生"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小林, 宏一郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"本間, 尚樹"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 敦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"JONES, Michael"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-01-30"}],"displaytype":"detail","filename":"tjsmbe-vannual59p400.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"tjsmbe-vannual59p400","url":"https://iwate-u.repo.nii.ac.jp/record/15905/files/tjsmbe-vannual59p400.pdf"},"version_id":"221d7479-9341-4842-9dcd-81bc84ec2d54"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"RGBカメラを用いた非接触酸素濃度推定技術に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"RGBカメラを用いた非接触酸素濃度推定技術に関する研究"},{"subitem_title":"Study on Non-Contact Oxygen Saturation Estimation using an RGB Camera","subitem_title_language":"en"}]},"item_type_id":"16","owner":"19","path":["1519"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-01-30"},"publish_date":"2023-01-30","publish_status":"0","recid":"15905","relation_version_is_last":true,"title":["RGBカメラを用いた非接触酸素濃度推定技術に関する研究"],"weko_creator_id":"19","weko_shared_id":-1},"updated":"2023-05-15T12:40:25.879849+00:00"}