{"created":"2023-05-15T12:04:26.549972+00:00","id":8990,"links":{},"metadata":{"_buckets":{"deposit":"7bba4048-ef57-4138-afbc-f847b2253b27"},"_deposit":{"created_by":3,"id":"8990","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"8990"},"status":"published"},"_oai":{"id":"oai:iwate-u.repo.nii.ac.jp:00008990","sets":["1504:1506"]},"author_link":["71153","71152","71149","71156","71155","71151","71150","71154"],"item_41_alternative_title_23":{"attribute_name":"その他のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Fundamental study on the fire resistance of binder-less wood shaving insulation panels"}]},"item_41_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03-29","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"38","bibliographicPageEnd":"21","bibliographicPageStart":"1","bibliographic_titles":[{"bibliographic_title":"岩手大学農学部演習林報告"}]}]},"item_41_date_6":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2011-08-17"}]},"item_41_description_12":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"本研究で開発中の木質小片断熱材は,プレーナー屑を密度100kg/㎥程度に圧縮し,建築用防湿フイルムで被覆して製造される。被覆材,小片ともに可燃性であり,小片間隙が火炎伝播を助長する可能性があるなどの理由から,開発当初より防火性が懸念されてきた。そこで本報告では,本断熱材の燃焼挙動に関する基礎知見を得る目的で,厚さ50mmの小型試験体を用いた加熱試験を行った。加熱はISO 834に規定される標準加熱温度曲線をほぼ満たす条件で行われ,断熱材の片面を直接加熱する場合と石膏ボード(厚さ12.5mm)を介して間接加熱する場合の2通りとした。また,間接加熱ではグラスウールを対照材料とし,遮熱性を比較した。\n直接加熱(12分間)の場合,炭化深さは25~30mmで裏面温度は80℃程度であった。間接加熱では加熱30分後に,これと同等の炭化深さおよび裏面温度に達した。一方,グラスウール(密度16kg/㎥,厚さ50mm)の場合,間接加熱30分後の裏面温度は158℃に達し,遮熱性は本断熱材の方が優れた。加熱後の試験体観察や含水率測定の結果,本断熱材の遮熱効果は,炭化層の形成に加えて,フイルム被覆による水分残存で発揮されることが分かった。凝結水の蒸発潜熱の消費により,比較的長時間にわたって100℃以下の裏面温度に保持されることが本断熱材の特徴と言える。","subitem_description_type":"Other"},{"subitem_description":"The insulation panels developed in this study for building purposes are composed of wood shavings compressed into a mat with a density of 100kg/㎥ without any binder. This mat is lapped with plastic film that works as a damp-proof course. Fire safety is an important concern because our panels consist of woods havings with gaps between them and other flammable raw materials. This paper describes fire tests conducted with a 50-\nmm-thick, small-scale specimen in order to obtain basic information about the fire resistance of our panels.\nTwo types of fire tests were conducted: one type involved direct heating from one surface, and the other involved indirect heating using a 12.5-mm-thick plaster board as a cover. The small vertical furnace that was used provided a heating temperature that almost satisfied the heating curve specified in the ISO 834 standard. The results revealed that 12 min of direct heating caused charring to a depth of 25 to 30 mm; however, the unexposed side (rear surface)temperature was approximately 80℃. In the case of indirect heating, such a charring depth required 30 min of heating with the rear surface temperature maintained below 80℃ during the heating time. Fiberglass insulation materials were also tested by indirect heating for the purpose of comparison. The rear surface temperature of a 50-mm-thick fiberglass with a density of 16kg/㎥ was found to be 158℃ after heating for 30 min; this suggests that our panels exhibit higher heat shielding performance than the\nfiberglass. It is clear that the charring layer acted as an insulator. Interestingly, moisture content measurements revealed that some of the water that remained near the rear surface of the panels provided heat shielding.","subitem_description_type":"Other"}]},"item_41_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"SEKINO, Noboru"}]},{"nameIdentifiers":[{}],"names":[{"name":"YOSHIBA, Megumi"}]},{"nameIdentifiers":[{}],"names":[{"name":"TANIUCHI, Hironori"}]},{"nameIdentifiers":[{}],"names":[{"name":"YAMAUCHI, Go"}]}]},"item_41_publisher_14":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"岩手大学農学部附属寒冷フィールドサイエンス教育研究センター"}]},"item_41_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0286-4339","subitem_source_identifier_type":"ISSN"}]},"item_41_text_4":{"attribute_name":"著者(機関)","attribute_value_mlt":[{"subitem_text_value":"岩手大学農学部農林環境科学科森林科学講座"},{"subitem_text_value":"岩手大学農学部農林環境科学科森林科学講座"},{"subitem_text_value":"岩手県林業技術センター林産利用部"},{"subitem_text_value":"(株)ヤマウチ"}]},"item_41_version_type_27":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"関野, 登"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"葭葉, 恵"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"谷内, 博規"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山内, 剛"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-14"}],"displaytype":"detail","filename":"biuf-n38p1-21.pdf","filesize":[{"value":"2.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"biuf-n38p1-21.pdf","url":"https://iwate-u.repo.nii.ac.jp/record/8990/files/biuf-n38p1-21.pdf"},"version_id":"7289f4b3-888d-4692-b3c3-eeb3742ed008"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"木質小片断熱材の防火性能に関する基礎的研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"木質小片断熱材の防火性能に関する基礎的研究"}]},"item_type_id":"41","owner":"3","path":["1506"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-08-17"},"publish_date":"2011-08-17","publish_status":"0","recid":"8990","relation_version_is_last":true,"title":["木質小片断熱材の防火性能に関する基礎的研究"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-16T11:19:49.801094+00:00"}