{"created":"2023-05-15T12:04:34.605426+00:00","id":9132,"links":{},"metadata":{"_buckets":{"deposit":"b05be85e-13fd-4981-810e-569c4595d9a3"},"_deposit":{"created_by":3,"id":"9132","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9132"},"status":"published"},"_oai":{"id":"oai:iwate-u.repo.nii.ac.jp:00009132","sets":["1504:1510"]},"author_link":["71860","71859","71862","71858","71857","71861"],"item_16_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicPageEnd":"386","bibliographicPageStart":"380","bibliographicVolumeNumber":"51","bibliographic_titles":[{"bibliographic_title":"木材学会誌"}]}]},"item_16_date_6":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-10-22"}]},"item_16_description_12":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"プレーナー屑を原料とする建築用バインダレス断熱パネル (密度100 kg/m3) を, 厚さ50~150 mmの範囲で製造した。非定常温度スケジュールにおける壁内一次元熱流を測定し, 断熱性と蓄熱性に及ぼすパネル厚さの影響を調べると同時に, 本断熱パネルの熱的性質を市販のグラスウールおよびフェノールフォームと比較した。得られた結果を要約すると, 1) 実用的な厚さ範囲 (100~150 mm) でほぼ一定の熱伝導率 (0.060 W/mK) を示した。2) 同一熱抵抗を持つグラスウールやフェノールと比較して壁体への流入熱量が抑制され, 保温性の優位性が示唆された。3) 熱拡散率 (0.41 × 10-6 m2/s) はグラスウールの約1/2, フェノールフォームの約3/4となり, 蓄熱効果による保温性が期待できる。","subitem_description_type":"Other"}]},"item_16_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"71860","nameIdentifierScheme":"WEKO"}],"names":[{"name":"SEKINO, Noboru"}]},{"nameIdentifiers":[{"nameIdentifier":"71861","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KAWAMURA, Yoshihiro"}]},{"nameIdentifiers":[{"nameIdentifier":"71862","nameIdentifierScheme":"WEKO"}],"names":[{"name":"YAMAUCHI, Go"}]}]},"item_16_publisher_14":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本木材学会"}]},"item_16_relation_26":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type":"isIdenticalTo","subitem_relation_type_id":{"subitem_relation_type_id_text":"10.2488/jwrs.51.380","subitem_relation_type_select":"DOI"}}]},"item_16_rights_18":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"Copyright (c) 2006 日本木材学会"}]},"item_16_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0021-4795","subitem_source_identifier_type":"ISSN"}]},"item_16_text_4":{"attribute_name":"著者(機関)","attribute_value_mlt":[{"subitem_text_value":"岩手大学農学部"},{"subitem_text_value":"岩手大学農学部"},{"subitem_text_value":"(株)ヤマウチ"}]},"item_16_version_type_27":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"関野, 登"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"河村, 義大"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山内, 剛"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-14"}],"displaytype":"detail","filename":"mg-v51n6p380-386.pdf","filesize":[{"value":"3.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"mg-v51n6p380-386.pdf","url":"https://iwate-u.repo.nii.ac.jp/record/9132/files/mg-v51n6p380-386.pdf"},"version_id":"1ae447fd-ca42-4d71-97b4-1a9c7ad9c716"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"insulation panel","subitem_subject_scheme":"Other"},{"subitem_subject":"wood shavings","subitem_subject_scheme":"Other"},{"subitem_subject":"thermal conductivity","subitem_subject_scheme":"Other"},{"subitem_subject":"thermal diffusivity","subitem_subject_scheme":"Other"},{"subitem_subject":"heat storage capacity","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"残廃材を原料とした建築用バインダレス小片断熱パネル (第4報)プレーナー屑を原料とした実大厚さパネルの蓄熱効果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"残廃材を原料とした建築用バインダレス小片断熱パネル (第4報)プレーナー屑を原料とした実大厚さパネルの蓄熱効果"}]},"item_type_id":"16","owner":"3","path":["1510"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-10-22"},"publish_date":"2009-10-22","publish_status":"0","recid":"9132","relation_version_is_last":true,"title":["残廃材を原料とした建築用バインダレス小片断熱パネル (第4報)プレーナー屑を原料とした実大厚さパネルの蓄熱効果"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-16T11:14:08.896214+00:00"}