WEKO3
インデックスリンク
アイテム
Evaluation of Macroscopic Elastic Properties of Porous Compacts Prepared by Powder Pressure Sintering for Biomedical Implant
https://iwate-u.repo.nii.ac.jp/records/9679
https://iwate-u.repo.nii.ac.jp/records/9679b4ff180a-689b-4238-8efa-dd10158629e7
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2008-12-25 | |||||||||
タイトル | ||||||||||
タイトル | Evaluation of Macroscopic Elastic Properties of Porous Compacts Prepared by Powder Pressure Sintering for Biomedical Implant | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Powder Compaction | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Simulation | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Elastic Modulus | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Anisotropy | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Human Bone | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
著者 |
TAGUCHI, Isao
× TAGUCHI, Isao
× KURASHIGE, Michio
|
|||||||||
著者(機関) | ||||||||||
値 | Graduate School of Engineering, Iwate University | |||||||||
著者(機関) | ||||||||||
値 | Department of Mechanical Engineering, Iwate University | |||||||||
登録日 | ||||||||||
日付 | 2008-12-25 | |||||||||
書誌情報 |
Journal of Solid Mechanics and Materials Engineering 巻 1, 号 3, p. 287-298, 発行日 2007-01-01 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 1880-9871 | |||||||||
Abstract | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | Macroscopic elastic properties of porous compacts prepared by applying uniaxial pressure in powder sintering are numerically estimated, with their biomedical application in mind. The estimation is based on a three step simulation method similar to the previous one. It is found that the compaction by the pressure and the sintering lead to increase in the macroscopic elastic moduli in the pressure direction, which is made to coincide with that of gravity in packing. It is also found that these moduli are larger than those in the direction normal to the pressure by 20% to 40%. Those for the less sintered compacts whose porosity ranges from approximately 32% to 37% fall in those of human cortical bone and show similar behavior to those of artificial implants. | |||||||||
出版者 | ||||||||||
出版者 | 社団法人日本機械学会 | |||||||||
権利 | ||||||||||
権利情報 | © 社団法人日本機械学会 | |||||||||
DOI | ||||||||||
関連タイプ | isIdenticalTo | |||||||||
識別子タイプ | DOI | |||||||||
関連識別子 | 10.1299/jmmp.1.287 | |||||||||
著者版フラグ | ||||||||||
出版タイプ | VoR | |||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |