{"created":"2023-05-15T12:05:07.776592+00:00","id":9746,"links":{},"metadata":{"_buckets":{"deposit":"3251ab18-a63c-480c-b449-216aa82a72f3"},"_deposit":{"created_by":3,"id":"9746","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"9746"},"status":"published"},"_oai":{"id":"oai:iwate-u.repo.nii.ac.jp:00009746","sets":["1515:1519"]},"author_link":["60584","60580","60583","60582","60581"],"item_16_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-01-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"966","bibliographicPageStart":"963","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"Transactions of the Materials Research Society of Japan"}]}]},"item_16_date_6":{"attribute_name":"登録日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2009-09-01"}]},"item_16_description_12":{"attribute_name":"Abstract","attribute_value_mlt":[{"subitem_description":"Stainless steels are one of the most promising materials as bipolar plates for polymer electrolyte membrane\nfuel cells(PEFCs). In use of stainless steel bipolar plates, however, corrosion and corrosion induced degradation of cell performance are anticipated. In the present study, corrosion behavior of SUS 304 and 310S stainless steels was investigated through polarization tests in the simulated PEFC envtronment(0.05M Na2SO4(pH2.3)+2ppmF solution at 353K), contact resistance measurement between steels and carbon diffusion layer and cell operation.XPS analysis was also carried out to compare the steel surfaces after polarization measurements and cell operation. The results indicated that passive current density for\nSUS 3lOS stainless steel in the simulated PEFC environments was lower than that for SUS 304 stainless steel, as expected from higher Cr content. Longer polarization of these steels decreased the passive current\ndensity but increased contact resistance due to thickening of the passive film.The cell voltage drops after 3.6 x lO^6 s operation were 14 mV for graphite, 22 mV for SUS 310S and 46 mV for SUS 304 steel.\nApparent corrosion was recognaized for SUS 304 stainless steel served for cathode.","subitem_description_type":"Other"}]},"item_16_publisher_14":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本MRS"}]},"item_16_rights_18":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"日本MRS"}]},"item_16_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1382-3469","subitem_source_identifier_type":"ISSN"}]},"item_16_text_4":{"attribute_name":"著者(機関)","attribute_value_mlt":[{"subitem_text_value":"Department of Chemical Engineering, Faculty of Engineering,Iwate University"},{"subitem_text_value":"Department of Chemical Engineering, Faculty of Engineering,Iwate University"},{"subitem_text_value":"Department of Chemical Engineering, Faculty of Engineering,Iwate University"},{"subitem_text_value":"Taiyo Stainless Spring Co., Ltd."},{"subitem_text_value":"Taiyo Stainless Spring Co., Ltd."}]},"item_16_version_type_27":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"YASHIRO, Hitoshi"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"ASAISHI, Ryo"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KUWATA, Shiho"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KUMAGAI, Masanobu"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YAO, Atsushi"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-11-14"}],"displaytype":"detail","filename":"tmrsj-v32n4p963-966.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"tmrsj-v32n4p963-966.pdf","url":"https://iwate-u.repo.nii.ac.jp/record/9746/files/tmrsj-v32n4p963-966.pdf"},"version_id":"75a0a367-075c-4161-b502-e37d4748364c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"bipolar plate","subitem_subject_scheme":"Other"},{"subitem_subject":"PEFC","subitem_subject_scheme":"Other"},{"subitem_subject":"stainless steel","subitem_subject_scheme":"Other"},{"subitem_subject":"corrosion","subitem_subject_scheme":"Other"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Corrosion of Stainless Steel Bipolar Plates in PEFC","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Corrosion of Stainless Steel Bipolar Plates in PEFC"}]},"item_type_id":"16","owner":"3","path":["1519"],"pubdate":{"attribute_name":"公開日","attribute_value":"2009-09-01"},"publish_date":"2009-09-01","publish_status":"0","recid":"9746","relation_version_is_last":true,"title":["Corrosion of Stainless Steel Bipolar Plates in PEFC"],"weko_creator_id":"3","weko_shared_id":-1},"updated":"2023-05-16T11:59:08.633228+00:00"}