The rejection of magnetic noise from the wire using independent component analysis for magnetocardiogram

https://iwate-u.repo.nii.ac.jp/records/9779
https://iwate-u.repo.nii.ac.jp/records/9779
0bd163de-4884-42d8-89e5-0c7c898a1160
名前 / ファイル ライセンス アクション
itm-v41n10p4152-4154.pdf itm-v41n10p4152-4154.pdf (851.5 kB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-09-10
タイトル
タイトル The rejection of magnetic noise from the wire using independent component analysis for magnetocardiogram
キーワード
主題Scheme Other
主題 High pass filter
キーワード
主題Scheme Other
主題 independent component analysis
キーワード
主題Scheme Other
主題 magnetocardiogram
キーワード
主題Scheme Other
主題 signal processing
キーワード
主題Scheme Other
主題 wire noise
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 Kobayashi, Koichiro

× Kobayashi, Koichiro

Kobayashi, Koichiro

Search repository
Uchikawa, Yoshinori

× Uchikawa, Yoshinori

Uchikawa, Yoshinori

Search repository
Shimizu, Tomoharu

× Shimizu, Tomoharu

Shimizu, Tomoharu

Search repository
Nakai, Kenji

× Nakai, Kenji

Nakai, Kenji

Search repository
Yoshizawa, Masahito

× Yoshizawa, Masahito

Yoshizawa, Masahito

Search repository
著者(機関)
値 Faculty of Engineering, Iwate University
著者(機関)
値 Faculty of Science and Engineering, Tokyo Denki University
著者(機関)
値 Faculty of Engineering, Iwate University
著者(機関)
値 Laboratory of Medicine, Iwate Medical University
著者(機関)
値 Faculty of Engineering, Iwate University
登録日
日付 2009-09-10
書誌情報 IEEE Transactions on Magnetics

巻 41, 号 10, p. 4152-4154, 発行日 2005-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0018-9464
Abstract
内容記述タイプ Other
内容記述 In magnetocardiogram (MCG) measurements, the magnetic noise from the wire used to suture the sternum after heart surgery becomes a problem. As one method of noise rejection, independent component analysis is effective. In this study, MCG measurements were carried out under the conditions that the wire was attached to a normal subject and that the wire was not attached. Signal processing by independent component analysis, digital high-pass filter and singer value decomposition analysis were carried out in order to reduce the effect of magnetic noise from the wire. From the comparison of the waveforms after this signal processing and the waveforms where the wire was not attached, it was apparent that the magnetic noise from the wire was reduced by independent component analysis. From this result, it is clear that independent component analysis is effective for the removal of the magnetic noise from the wire.
出版者
出版者 IEEE
権利
権利情報 © 2005 IEEE
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.1109/TMAG.2005.854851
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 14:54:28.318422
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3