Fundamental Imaging Properties of Transillumination Laser Computed Tomography Based on Coherent Detection Imaging Method

https://iwate-u.repo.nii.ac.jp/records/9759
https://iwate-u.repo.nii.ac.jp/records/9759
9f7f8716-7b40-4943-bc88-d9647c2f6a99
名前 / ファイル ライセンス アクション
ac-v18n12p1329-1333.pdf ac-v18n12p1329-1333.pdf (1.8 MB)
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-09-03
タイトル
タイトル Fundamental Imaging Properties of Transillumination Laser Computed Tomography Based on Coherent Detection Imaging Method
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
著者 YUASA, Tetsuya

× YUASA, Tetsuya

YUASA, Tetsuya

Search repository
TANOSAKI, Shinji

× TANOSAKI, Shinji

TANOSAKI, Shinji

Search repository
SASAKI, Yoshiaki

× SASAKI, Yoshiaki

SASAKI, Yoshiaki

Search repository
TAKAGI, Michiaki

× TAKAGI, Michiaki

TAKAGI, Michiaki

Search repository
SHIKAWA, Akira

× SHIKAWA, Akira

SHIKAWA, Akira

Search repository
TANIGUCHI, Hiroshi

× TANIGUCHI, Hiroshi

TANIGUCHI, Hiroshi

Search repository
DEVARAJ, Balasigamani

× DEVARAJ, Balasigamani

DEVARAJ, Balasigamani

Search repository
AKATSUKA, Takao

× AKATSUKA, Takao

AKATSUKA, Takao

Search repository
著者(機関)
値 Faculty of Engineering, Yamagata University
著者(機関)
値 I. T. Research Co., Ltd.
著者(機関)
値 Faculty of Engineering, Yamagata University
著者(機関)
値 School of Medicine, Yamagata University
著者(機関)
値 School of Medicine, Yamagata University
著者(機関)
値 Faculty of Engineering, Iwate University
著者(機関)
値 New Focus Corp.
著者(機関)
値 Faculty of Engineering, Yamagata University
登録日
日付 2009-09-03
書誌情報 Analytical Sciences

巻 18, 号 12, p. 1329-1333, 発行日 2002-01-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
Abstract
内容記述タイプ Other
内容記述 The coherent detection imaging (CDI) method the optical heterodyne detection technique. CW and single frequency lasers having long coherence lengths are used to exploit the maximum advantages of heterodyne detection, such as high directionality, selectivity and sensitivity. The CDI method based on optical heterodyne detection enables selective filtering of the directional coherence-retaining emergent photons, which leads to image reconstruction from projections, similar to X-ray computed tomography (CT). So far we have demonstrated the advantages and capabilities of the measurement technique for transillumi-nation optical computed tomography in biomedicine. Here, we investigate the fundamental imaging properties of CDI method, such as its high directionality and quantitativeness, with preliminary physical phantom experiments. The results show that the CDI method satisfies the requirements for CT reconstruction under the first order approximation, and enables quantitative measurements in the sense that the relationship between estimated and actual concentration retains a satisfactory linearity.
出版者
出版者 The Japan Society for Analytical Chemistry
権利
権利情報 Copyright (c) 2005 by The Japan Society for Analytical Chemistry
DOI
関連タイプ isIdenticalTo
識別子タイプ DOI
関連識別子 10.2116/analsci.18.1329
著者版フラグ
出版タイプ VoR
出版タイプResource http://purl.org/coar/version/c_970fb48d4fbd8a85
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 14:54:52.145556
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3