WEKO3
インデックスリンク
アイテム
多孔壁に沿って伝ぱする衝撃波背後の流れの解析と壁面流出係数
https://iwate-u.repo.nii.ac.jp/records/9881
https://iwate-u.repo.nii.ac.jp/records/9881820eb03b-0d36-4a67-8ffd-b005dca04f8b
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2009-11-27 | |||||||||
タイトル | ||||||||||
タイトル | 多孔壁に沿って伝ぱする衝撃波背後の流れの解析と壁面流出係数 | |||||||||
言語 | ||||||||||
言語 | jpn | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Compressible Flow | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Flow Measurement | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Discharge Coefficient | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Holographic Interferometry | |||||||||
キーワード | ||||||||||
主題Scheme | Other | |||||||||
主題 | Numerical Simulation | |||||||||
資源タイプ | ||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||
資源タイプ | journal article | |||||||||
著者 |
小野寺, 英輝
× 小野寺, 英輝
× 高山, 和喜
|
|||||||||
著者別名 | ||||||||||
識別子Scheme | WEKO | |||||||||
識別子 | 61386 | |||||||||
姓名 | ONODERA, Hideki | |||||||||
著者別名 | ||||||||||
識別子Scheme | WEKO | |||||||||
識別子 | 61387 | |||||||||
姓名 | TAKAYAMA, Kazuyoshi | |||||||||
著者(機関) | ||||||||||
値 | 岩手大学工学部 | |||||||||
著者(機関) | ||||||||||
値 | 東北大学流体科学研究所 | |||||||||
登録日 | ||||||||||
日付 | 2009-11-27 | |||||||||
書誌情報 |
日本機械学會論文集. B編 巻 58, 号 549, p. 1408-1412, 発行日 1992-01-01 |
|||||||||
ISSN | ||||||||||
収録物識別子タイプ | ISSN | |||||||||
収録物識別子 | 0387-5016 | |||||||||
Abstract | ||||||||||
内容記述タイプ | Other | |||||||||
内容記述 | Shock wave propagation over a perforated wall and wall discharge coefficient through the perforation were studied experimentally and numerically. The experiment was conducted in a shock tube equipped with double-exposure holographic interferometry. Shock Mach number was 1.54 in air and the wall perforation ratio was 0.4. The numerical simulation was conducted by an upwind finite difference scheme using the TVD scheme. To determine the wall discharge coefficient through the perforation, the numerical result was compared with the experimental one. The wall discharge coefficient through the perforation was obtained as 0.54, and this value can be extended to the perforation ratio ranging from 0.1 to 0.5, a shock wave Mach number of 1.5 to 5.5 and a corresponding Reynolds number of 1.24×10^5 to 9.78×10^5. | |||||||||
出版者 | ||||||||||
出版者 | 社団法人日本機械学会 | |||||||||
権利 | ||||||||||
権利情報 | 社団法人日本機械学会 | |||||||||
権利 | ||||||||||
権利情報 | 本文データは学協会の許諾に基づきCiNiiから複製したものである | |||||||||